Skip to main content
Skip table of contents

4.0.0 PC

Release date: 03 Mar. 2017

Updates

New and Improved Interface: 

  • Redesigned toolbars and icons.

  • Simplified inspection workflow.

  • Side by side inspection view. 

  • User-friendly profiles (setups) for the detection of differences.

  • Ability to access profiles (setups) directly from the main toolbar.

  • Graphics Inspection repeats are identified with Repeat IDs in the Overview window.

  • Ability to close loaded files.

  • Ability to navigate between file preview and inspection results without having to re-run an inspection.

New and Improved Functionality: 

  • Support for new file formats: DOC/ DOCX, HTML/ HTM, MHTML/ MHT, RTF, TXT, XLS/ XLSX, XML.

  • Ability to show live text in documents.

  • New PDF Engine (Adobe).

  • Ability to view process colors (CMYK).

  • Support for the selection of PDF boxes in the PDF Viewer (i.e., media, crop, trim).

  •  Ability to select different areas for inspection and generate inspection sets.

  • New graphics comparison mode for comparing booklets with pages in a different order (All Pages Unsorted).

  • New graphics comparison mode for comparing a single-page master to multiple instances in the sample file (Single to Many).

  • New graphics comparison mode for comparing multiple master files to multiple sample files for batch inspections and inspecting ganged sheets (Many to Many).

  • Ability to select and filter pages of a multi-page file easily for inspection.

  • New multi-inspection mode for running different inspection modes at the same time (Graphics, Barcode, and Braille).

  • Support for additional Barcode types (Code 93, Laetus Pharmacode, EAN-5, EAN-2, ITF-14, ITF-16, GS1 Databar Omnidirectional, GS1 Databar Truncated, GS1 Databar Stacked Omnidirectional).

  • Additional parameters displayed for ITF interleaved 2 of 5, Code 39, Codabar, and MSI barcodes (Wide to Narrow Ratio and Grading).

  • Additional parameters displayed for Data Matrix, QR Code, and Micro QR Code barcodes (Quiet Zone).

  • Ability to provide a measurement DPI in Barcode module to allow for higher accuracy when performing barcode measurements (i.e., BWR).

  • GS1 Data structure information included as part of barcode grading (optional).

  • Support for detection of rotated barcodes at non-90-degree angles (i.e., 30, 45).

  • Support for the European Blind Union (EBU) Code language in Braille Inspection.

  • Ability to create/ maintain Braille languages (profiles).

  • Ability to create/ maintain Barcode profiles to adjust the detection parameters/ criteria for barcode detection, grading, resolution, and speed.

  • Support for identification of Braille dot diameter and spacing deviations from the ISO Standard 17351:2013.

  • Ability to generate a single report for multiple inspection sets.

  • Ability to select levels to include in the report.

  • Ability to exclude signature fields (Performed By, Reviewed By) in the report. 

  • Improved Graphics Inspection report with the addition of the difference image and radio boxes for levels.

  • Addition of Manager role with the ability to create/ maintain profiles (setups) and report settings.

Bug Fixes

  • Improved stability for Mac platform. 

  • Improved separation handling (i.e., turning off a separation/ removing separations) to correct file specific issues with missing text or elements.

  • Improved overprint preview functionality (colors and text displayed correctly) to correct file-specific issues with incorrect colors and bleeding.

  • Improved PDF handling (i.e., displayed colors match Adobe colors) to correct file specific issues for incorrect text display (bold, size, and font).

  • Overprint preview is now applied to all pages of a multi-page file.

  • Dieline is no longer automatically hidden for shape extraction.

  • Improved barcode detection for all barcode types.

  • Improved consistency of barcode-grading results. 

  • Improved precision for Bar Width Reduction values and grading. 

  • Barcodes are graded correctly for reduced-magnification barcodes.

  • Ability to detect very small Pharmacode barcodes (sample-specific)

  • Barcode graded as Fail (F) if a quiet zone is graded "F" and grading of NON-ISO parameters is enabled.

  • Long barcode-decoded values are displayed correctly to ensure they do not overlap other parameters in the report.

  • Zoom level for barcode thumbnails in the PDF report reduced to display the human-readable data correctly.

  • Updated Braille languages based on PharmaBraille.

  • Number flag (#) no longer displayed in Braille translations.

  • Uppercase flag (↑) no longer displayed in Braille translations.

  • Updates made to the following Braille Languages: Czech, Danish, Estonian, Finnish, German, Greek, Icelandic, Dutch, Norwegian, Polish, Portuguese, Romanian, Slovene.

  • Consistent results obtained when files are reversed (sample-specific).

  • The application does not crash when Use the following page for region selection is enabled (sample-specific).

  • Ability to trim after cropping to contents functionality is used (sample-specific).

  • Ability to use the level hotkeys (F1-F5) for multiple selected differences.

  • Ability to enter 5 lines of comments containing 60 characters on each line per difference.

  • Custom comments are automatically applied to a difference even if the focus is moved away from the comments window. 

  • The first detected difference is not automatically set to reviewed (only set to reviewed once reviewed).

  • For multiple-page inspections, the first difference on each page is not automatically set to review when the user navigates through each page.  

  • A report is generated where the Force Review of Differences option is enabled and the inspection set is excluded and not reviewed.

  • A new location for custom report headers.
    o Message displayed when a file cannot be loaded due to password protection. 

  • A message displayed to indicate invalid characters used in profile (setup) name.

  • Unable to enter a blank profile (setup) name.

  • Correct rastered DPI value displayed in the Information panel. 

  • Golden Master file name displayed in the header of the inspection report.

  • Image is displayed in the Master or Sample Panel after the Information panel is opened even for very large files (sample-specific).

  • Image size and memory size values are displayed correctly in the Information panel.

  • Inspection Wizard replaced with Product Information form only.

  • Ability to connect the Login Management module to all ports. 

  • Addition of audit events for password expiry and import profile actions. 

  • Improved descriptions for audit trail events.

  • Audit Trail event no longer logged when the user closes the PDF Viewer window.

  • The arrow is visible for the Action drop-down list for Audit Trail and User Maintenance functions.

  • The User list is sorted alphabetically in ascending or descending order.

  • The user list and Audit Trail headings are aligned when printed.

  • Support for centralized profiles (MAC).

  • Support for files with security permissions.

  • Ability to load files containing Cyrillic characters.

  • Ability to delete reports saved on the server (MAC).

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.